The KnightLighter ™ Automatic Gaslight Igniter is an “Electronic Ignition System” available from Vulcan Lighting that provides Automatic Operation of an open flame or mantle gaslight/lantern. Customers can now have the convenience of turning the gaslight on and off automatically without the need for ladders or lighters.
A photo-sensor signal keeps the light off during daylight hours, and turns the light on automatically each evening. The KnightLighter ™ Automatic Gaslight Igniter will also automatically re-ignite the lantern should the flame be blown out.
Vulcan Lighting offers both a 24VAC and a convenient Battery powered model. The battery model is very useful for retrofitting existing gaslight installations.
The 24VAC Model can be used for new gaslight installations and can be used with a wall switch, timer, or remote control as well as the automatic photo-sensor control.
Igniter operating and installation instructions are available and will accompany the purchase of each igniter system.
Is the gas light igniter safe for indoor use?
Knightronix™ does not recommend using the KnightLighter ™ Automatic Gaslight Igniter indoors. Vulcan Lighting offers several burner designs using a Gas Light Thermal Safety Shutoff Valve that is approved for indoor or outdoor use.
All Legendary Lighting natural gas and propane gas lanterns equipped with either electronic ignition or automatic shutoff valve are C.S.A. Certified to comply with ANSI Standard Z21.42 for indoor or outdoor use.
The KnightLighter ™ Automatic Gaslight Igniter is a
convenient way of lighting your gaslight as well as making sure that is stays
lit. It is especially useful in situations where gaslights are installed in
higher locations as over doors, or posts, where ladders are needed to turn
lights on and off. Also, the KnightLighter™ Automatic Gaslight Igniter conserves
50% on gas consumption by shutting off the gaslight during daylight hours and
automatically turning it on at night. The KnightLighter ™ Automatic Gaslight Igniter is designed
to be installed in the bottom of the gaslight head. It should fit near the
floor of the gaslight so as to be inconspicuous. Vulcan Lighting would be happy to help you
with customized igniter integrations;
Contact Us,
for more information. General installation instructions:
Install the igniter in the bottom of the gaslight head.
Connect to a 1/8"copper coil or flex gas line by tightening
the 1/4" Flare Nut onto a 1/4"x 1/8" Flare fitting on the input to the
gas light valve of the igniter, pushing the copper tubing down into the post (for post
installations). The Model KNA1-24V Igniter shall be connected only to
24vac +/-4vac. DO NOT CONNECT DIRECT TO 120 VAC. A transformer is used
to convert 120 VAC to 24 VAC, and can be supplied by the customer or
purchased through Vulcan Lighting. The Battery model runs on 4AA batteries that should last
for approx. one year. Igniter operating and installation instructions are
available and will accompany the purchase of each igniter system. Please see our
Pricing,
Information, and
Benefits listings for more information
on the KnightLighter™ Automatic Gaslight Igniter. Yes, we do offer Dealer Pricing as well as reduced shipping
cost on quantity orders.
Contact Us,
for more information. Payment for the purchased gaslight equipment can be made by
credit card via PayPal at the time the order is placed or a check or money order
can be included with a manual order, sent by U.S. mail. Back to Top